Kodak film data
l film 'n develop
KODAK Developer D-76
KODAK Film EI 18°C (65°F) 20°C (68°F) 21°C (70°F) 22°C (72°F) 24°C (75°F)
T-MAX 100 Professional 100/200 - 6 1/2 6 5 1/2 5
400 - 9 8 1/2 8 7
800 NR NR NR NR NR
T-MAX 400 Professional 400 - 6 1/2 6 1/2 6 5 1/2
800 - 7 6 1/2 6 5 1/2
1600 - 9 8 1/2 8 7
3200 NR NR NR NR NR
T-MAX P3200 Professional 400 - 8 7 1/2 7 1/4 6 1/2
800 - 8 1/2 8 7 3/4 7
1600 - 9 8 1/2 8 7 1/2
3200 - 11 1/2 11 10 1/2 9 1/2
6400 - 13 1/2 13 12 11
PLUS-X Pan / PX 125 5 1/2 5 4 3 1/2 3
PLUS-X Pan Professional / PXP 125 7 6 5 4 1/2 4 1/2
TRI-X Pan 400/800 7 1/2 7 6 5 4
1600 - - 9 8 7
3200 - - 11 10 9 1/2
TRI-X Pan Professional 320 - 7 1/2 7 6 1/2 5 1/2
NR = Not recommended l NA = Not applicable

KODAK T-MAX RS Developer
Small-Tank Processing (8- or 16-ounce tank)--Rolls
KODAK T-MAX RS Developer and Replenisher
KODAK Film Speed Rating Development Time (Minutes)
EI ISO 18°C
(65°F)
20°C
(68°F)
21°C
(70°F)
22°C
(72°F)
24°C
(75°F)
27°C
(80°F)
29°C
(85°F)
T-MAX 100 Professional 100 or 200
400
800
-
-
-
NR
-
-
8
12
NR
7
11
NR
7
10
NR
6
9
11½
-
-
-
-
-
-
T-MAX 400 Professional 400 or 800
1600
3200
-
-
-
NR
-
-
7
10
13
6
9
12
6
8
11
5
7
-
-
-
-
-
-
T-MAX 3200 Professional 400*
800
1600
3200
6400
12,500*
25,000*
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8
9
10½
13
15
18
NR
7


12
14
16
NR



11
13
14
16
6


10
11
12
14

6
7
9
10
11
13
5

6
8
9
10
11
PLUS-X Pan
PLUS-X Pan Professional
250
500
or 125
-

NR

9
4½**
4**
3½**
-
-
-
-
TRI-X Pan 800
1600
3200
or 400
-
-
7
-
-
6

12

9
11½


11½
5
8
11
-
-
-
-
-
-
TRI-X Pan Professional - 320 5 4** 3½** 3½** 3** - -
VERICHROME Pan - 125 - 4** 4** 3½** 3½** - -
* Make tests to determine if results at these ratings are acceptable for your needs.
** Development times shorter than 5 minutes may produce unsatisfactory uniformity.
NR = Not recommended
Note: The development times in bold type are suggested starting points.
more info for kodak develper and film -> go to kodak D-76 l go to kodak T-max
KODAK T-MAX Developer
Small-Tank Processing (8- or 16-ounce tank)--Rolls
KODAK Film Speed Rating Development Time (Minutes)
EI ISO 20°C
(68°F)
22°C
(72°F)
24°C
(75°F)
T-MAX 100 Professional 100 or 200
400
800
-
-
-
8
12
NR
7
10
NR
6.5
9
10½
T-MAX 400 Professional 400 or 800
1600
3200
-
-
-
7
10
NR
6.5
8
NR
6
8
PLUS-X Pan
PLUS-X Pan Professional
250
500
or 125
-

NR
5
NR
5
9
TRI-X Pan 800
1600
3200
or 400
-
-
6
10
NR

9
NR
5.5
8.5
11